ITEM 項目
|
TEST CONDISTION測試條件
|
PERFORMANCE規(guī)格
|
6.ELECTRONICAL PERFORMANCE 電氣性能
|
6.1
|
CONTACT
RESISTANCE
接觸阻抗
|
Being measured at 1kHz small current
Contact resistance meter.
在1kHz小電流下測量.
|
30mΩ max.
30毫歐 以下.
|
6.2
|
INSULATION
RESISTANCE
絕緣阻抗
|
Measurements shall be made following
Application of Dc 500V potential
Across terminals and across terminals
And frame for 1 minute.
在端子之間和端子與殼之間加DC 500V
條件下,持續(xù)1分鐘測量.
|
100MΩ max.
100兆歐 以上.
|
6.3
|
WITHSTAND
VOLTAGE
耐電壓
|
AC 500V (50Hz or 60Hz) shall be
Applied across terminals and across terminals
And frame for 1 minute.
在端子之間和端子與殼之間加AC 500V
(50Hz或60Hz) 條件下,持續(xù)1分鐘測量.
|
There shall be no breakdown.
無擊穿現(xiàn)象出現(xiàn).
|
7.MECHANICAL PERFORMANCE 機械性能
|
7.1
|
OPERATING
FORCE
動作力
|
Measure at the point 3mm from the tip
Of the actuator (knob).
在距離推桿前端3mm作測定點.
|
350gf±100gf
|
7.2
|
TERMINAL
STRENGTH
端子強度
|
A static force of 500gf being applied
In one direction on the tip or the
Terminal for 1 minute.
一個500克之靜電負荷施加于端子頂部的一個方向持續(xù)1分鐘.
|
There shall be no sign of
damage mechanically and
electrically.
無任何跡象顯示機械及電器
性能之損壞.
|
7.3
|
ACTUATOR
STRENGTH
推桿強度
|
A static load of 1kgf being applied
In one direction of actuator for one min
一個1公斤靜負荷施加于推桿之一個方向持續(xù)
1分鐘.
|
The deformation shall not be
extreme and the actuator shall
mechanically work normally.
推桿無變形,可以正常操作.
|
ITEM 項目
|
TEST CONDISTION 測試條件
|
PEREORMALNCE 規(guī)格
|